Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
FS6X4WH6NM

FS6X4WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

1054

F2X1.5LG6-A

F2X1.5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

37

FS3X2LG6NM

FS3X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

8

FS4X4BL6NM

FS4X4BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

12342

G2X2WH6

G2X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

129384

G1.5X3LG6-A

G1.5X3LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

21

FS2X2LG6NM

FS2X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

1

LD10EI8-A

LD10EI8-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE IVRY 8'

160

F4X5LG6-A

F4X5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

1048

G1X4WH6

G1X4WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

716336

FR4X4BL6

FR4X4BL6

Panduit Corporation

WIRE DUCT SOLID BASE BRCKT MT 6'

101788

LDPH3WH10-A

LDPH3WH10-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 10'

0

G3X4WH6-A

G3X4WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

101272

F2X4BL6

F2X4BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 2" X 4

10126

TG70IW10

TG70IW10

Panduit Corporation

PWR RATED MULTICHAN RACEWAY 10'

401560

LDPH3EI10-A

LDPH3EI10-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 10'

0

F1.5X2BL6

F1.5X2BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 1.5" X

24

G1X3WH6-A

G1X3WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

1242

F1.5X2LG6-A

F1.5X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

1978

FS2X3LG6

FS2X3LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

12

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email