Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
FS4X2LG6

FS4X2LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

2042

DRD22LG6

DRD22LG6

Panduit Corporation

WIRE DUCT SLOTTED DIN RL FAST 6'

6

FS4X4WH6NM

FS4X4WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

12

G1X1.5LG6

G1X1.5LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

5829

FS2X2WH6

FS2X2WH6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

28

F1.5X4LG6-A

F1.5X4LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

618

F1.5X4WH6

F1.5X4WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

515750

MC50X50IG2

MC50X50IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

17280

T45BIW8-A

T45BIW8-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH WHT 8'

0

FS4X3WH6NM

FS4X3WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

0

D2X2LG6

D2X2LG6

Panduit Corporation

WIRE DUCT ROUND SCREW GRAY 6'

41

S4X4YL6NM

S4X4YL6NM

Panduit Corporation

WIRE DUCT SOLID BASE YELLOW 6'

6234

F1.5X1.5IB6

F1.5X1.5IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

1496

F1.5X3LG6

F1.5X3LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

23416908

F1X1.5LG6

F1X1.5LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

5410074

FS.5X.5LG6

FS.5X.5LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

15

G3X3BL6

G3X3BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

663162

FS2X1LG6NM

FS2X1LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

14

FS6X4LG6

FS6X4LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

106

LDPH10IG8-A

LDPH10IG8-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 8'

14411360

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top