Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G4X4LG6-A

G4X4LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

612

184-12000

184-12000

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

3240639

3240639

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

181-23091

181-23091

HellermannTyton

SLOTTED-WALL WIRING DUCT, 2.5" X

15

1485DZ12

1485DZ12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

SRWDN1-2030

SRWDN1-2030

Richco, Inc. (Essentra Components)

WIRE DUCT SLOTTED 2PC SCRW 6.50'

10

181-00225

181-00225

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

G2X2IB6

G2X2IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

33

184-05558

184-05558

HellermannTyton

HIGH-DENSITY SLOTTED-WALL WIRING

20

LDPH10IW6-A

LDPH10IW6-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCREW 6'

14312

181-11016

181-11016

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

3240620

3240620

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

HS2X4BL6NM

HS2X4BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

0

3240279

3240279

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

3240634

3240634

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

1487CT

1487CT

Hammond Manufacturing

WIREWAY TEE FITTING 4X4"

0

181-15106

181-15106

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

184-22050

184-22050

HellermannTyton

SLHD2.5X3 INTR BLUE PVC DUCT

0

LD3IW8-A

LD3IW8-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 8'

2012480

181-00200

181-00200

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top