Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
181-11013

181-11013

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

10

RX5050-4

RX5050-4

Richco, Inc. (Essentra Components)

WIRE DUCT FLEXIBLE ADH GRY 1.64'

95

G1X2LG6-A

G1X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCREW 6'

113618

F.75X.75WH6

F.75X.75WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

12114

3240317

3240317

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

5

AG40100-BOX

AG40100-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 1&1/2 X 4

2

181-15503

181-15503

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-33006

181-33006

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

G3X3WH6

G3X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

595082

PIK 100/60 VA

PIK 100/60 VA

PFLITSCH

CABLE TRAY BODY & COVER,

0

B60X60S/BU-R

B60X60S/BU-R

Altech Corporation

WIRE DUCT 60X60MM 2M LGTH(8) SLO

0

181-00663

181-00663

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

1485BJ

1485BJ

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

CWST696

CWST696

Hammond Manufacturing

COVER HINGED STRAIGHT 6X6X96"

0

B25X60S/BL-R

B25X60S/BL-R

Altech Corporation

WIRE DUCT 25X60MM 2M LENGTH BLK

0

CWSC418NK

CWSC418NK

Hammond Manufacturing

COVER SCREW STRAIGHT 4X4X18"

0

3240301

3240301

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

181-23011

181-23011

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

B80X60T/W-R

B80X60T/W-R

Altech Corporation

WIRE DUCT 80X60MM 2M LGTH(8) THI

0

B100X100T-R

B100X100T-R

Altech Corporation

WIRE DUCT 100X100MM 2M COVER

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top