Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
184-11006

184-11006

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

3240357

3240357

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

G2X1LG6-A

G2X1LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

16

HS2X2BL6NM

HS2X2BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

810

1486D48

1486D48

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 4'

0

TSR3W-6A

TSR3W-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

G1X2WH6-A

G1X2WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

7

181-32009

181-32009

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

AFR4BCBL6

AFR4BCBL6

Panduit Corporation

ABOVE FLOOR RACEWAY 4-CHANNEL BA

6

184-21003

184-21003

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

1485C48

1485C48

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 4'

0

FS3X2BL6NM

FS3X2BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

44

FWF-10521

FWF-10521

Quest Technology International

RACEWAY ONAROLL 1'' BEIGE 50 FT

6

G4X4LG6

G4X4LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

5

181-12002

181-12002

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

FRHD2KTYL

FRHD2KTYL

Panduit Corporation

WIRE DUCT SLOTTED 2PC BRKT MT 6'

3

G2X2WH6-A

G2X2WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

4102

1487D120

1487D120

Hammond Manufacturing

WIREWAY PULL THRGH 120" 6X6" GR

0

3240318

3240318

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

LDPH5WH10-A

LDPH5WH10-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 10'

400

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers