Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
FS4X1.5LG6

FS4X1.5LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

16

181-00499

181-00499

HellermannTyton

WIRE DUCT SOLID BASE ADH SCRW 6'

0

SG40100-BOX

SG40100-BOX

Tecnomatic Corp

SMALL FINGER GRAY DUCT 1&1/2 X 4

2

181-34007

181-34007

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

7

T45BIW8

T45BIW8

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 8'

3200

181-13008

181-13008

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

TNC37X75LG2

TNC37X75LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

1120

181-12004

181-12004

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

1485C60

1485C60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

1485D12

1485D12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

FS1X3LG6NM

FS1X3LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

15102

3240309

3240309

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

13

1486D18

1486D18

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 1.5'

0

F1X1.5LG6-A

F1X1.5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

101974

3240640

3240640

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

1030

3240322

3240322

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

10

LD10IW6-A

LD10IW6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 6'

3039960

F1X3LG6-A

F1X3LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

632862

181-15404

181-15404

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

9

FS1.5X1.5LG6NM

FS1.5X1.5LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

14

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers