Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
SG2580-BOX

SG2580-BOX

Tecnomatic Corp

SMALL FINGER GRAY DUCT 1X3 1 BO

5

G.75X1.5WH6-A

G.75X1.5WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

15

181-21007

181-21007

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

MC75X100WH2

MC75X100WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

4

181-45011

181-45011

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

FR6X4BL6

FR6X4BL6

Panduit Corporation

WIRE DUCT SOLID BASE BRCKT MT 6'

61740

181-00655

181-00655

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

13

181-33014

181-33014

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

TSRP3W-8A

TSRP3W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

181-23002

181-23002

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

FS2X2LG6

FS2X2LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

34258

LD5BL6-A

LD5BL6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE BLCK 6'

268

181-44033

181-44033

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

3240323

3240323

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

1

FS2X2BL6NM

FS2X2BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

22276

G.5X.5LG6-A

G.5X.5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

1636

184-11012

184-11012

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-44013

181-44013

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

G1X3WH6

G1X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

510026

F2X1WH6

F2X1WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

19

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top