Box Components

Image Part Number Description / PDF Quantity Rfq
2959337

2959337

Phoenix Contact

SIDE ELEMENT 5 MM WIDE

86350

2959719

2959719

Phoenix Contact

SIDE ELEMENT RIGHT W/FOOT

0

2943178

2943178

Phoenix Contact

COVER THE CONTACT & DUST-PROTECT

2

1481L3R1510GY

1481L3R1510GY

Hammond Manufacturing

VENT KIT GRAY

0

1455RPLTRD

1455RPLTRD

Hammond Manufacturing

BEZEL SOLID PLASTIC RED 2/PACK

10

1248210000

1248210000

Weidmuller

CH20M BUS-PROFIL TS 35X15/750

5

2202046

2202046

Phoenix Contact

HOUSING COMPONENT

0

2025,BK

2025,BK

Serpac Electronic Enclosures

BOX END PANEL BLK A42 9V SERIES

0

2941507

2941507

Phoenix Contact

ELECTRONIC HOUSING

0

2201814

2201814

Phoenix Contact

ELECTRONIC HOUSING BASE

35

CP2016G

CP2016G

nVent Hoffman

PANEL 18.20X14.20

34

1455TALBK-10

1455TALBK-10

Hammond Manufacturing

END PANEL ALUMINUM BLACK 10/PACK

11

2201960

2201960

Phoenix Contact

ME-IO 18 8 B/FE 9/9U TBUS 7035

10

EP4824

EP4824

Hammond Manufacturing

PANEL STEEL 46.2X22.2" WHT

0

PNX-91435

PNX-91435

Bud Industries, Inc.

PANEL ALUM 10.02X6.87X0.06"

6179

2201772

2201772

Phoenix Contact

ELECTRONIC HOUSING COVER

10

1431-22BK3

1431-22BK3

Hammond Manufacturing

COVER FOR CHASSIS 12X8" BLK

22

2907172

2907172

Phoenix Contact

HOUSING UPPER PART PRINT CIR

69

1590ZGRP162PL

1590ZGRP162PL

Hammond Manufacturing

PANEL INNER STEEL 9.6X5.6

7

AFPK86-IMP

AFPK86-IMP

Integra Enclosures

IMPACT 8X6 ALUMINUM FACE PLATE K

10

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top