Box Components

Image Part Number Description / PDF Quantity Rfq
1455CBTRD

1455CBTRD

Hammond Manufacturing

BEZEL OPEN PLASTIC RED 2/PACK

6

A10P8SS

A10P8SS

nVent Hoffman

PANEL J BOX 8.75X6.88

1

1054706

1054706

Phoenix Contact

ECS ENCLOSURE NON-VENTED

1015

2970028

2970028

Phoenix Contact

ELECTRONIC BOARD BASE

391780

2945406

2945406

Phoenix Contact

COVERING HOOD

0

2201518

2201518

Phoenix Contact

ELECTRONIC HOUSING COVER

0

2757144

2757144

Phoenix Contact

HOUSING PLSTC GRN 3.11"LX1.58"W

0

1455PBTRD

1455PBTRD

Hammond Manufacturing

BEZEL OPEN PLASTIC RED 2/PACK

16

30848327

30848327

Schroff / nVent

FRNT PNL 3U 4HP TYP 2 EXTRCT HDL

22

30848304

30848304

Schroff / nVent

FRNT PNL 6U 5HP TYP 2 EXTRCT HDL

0

1174280000

1174280000

Weidmuller

CH20M12 SIDE ELEMENT 3 LEVEL

0

DMB-4775-IRC

DMB-4775-IRC

Bud Industries, Inc.

INFRA RED REPLACEMENT COVER FOR

21151

2908744

2908744

Phoenix Contact

HOUSING BASE 5POS INTEGRATED

25

20817456

20817456

Schroff / nVent

FRONT PANEL KIT 3U 10HP VME

0

EPG2412

EPG2412

Hammond Manufacturing

PANEL STEEL 22.2 X 10.2"

0

1053051

1053051

Phoenix Contact

FILLER PLUGS

10040

1590ZGRP161PL

1590ZGRP161PL

Hammond Manufacturing

PANEL INNER STEEL 5.6X5.6

18

2792002

2792002

Phoenix Contact

HOUSING PLASTIC GREEN

73

1481L3R68GY

1481L3R68GY

Hammond Manufacturing

VENT KIT GRAY

0

PTX-25340-P

PTX-25340-P

Bud Industries, Inc.

PTS MOUNTING PLATE PLASTIC

55

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications